Mycotoxines

BiopureTM Alternariolmethylether - 100 µg/mL
10007351Mycotoxines AlternariaToxins Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Alternariolmethylether
- Technologie/Application: Calibrants
- Quantité/Montant: 1 mL

BiopureTM Alternariol - 100 µg/mL
10007350Mycotoxines AlternariaToxins Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Alternariol
- Technologie/Application: Calibrants
- Quantité/Montant: 1 mL

BiopureTM MIX 21 (Fumonisins B1, B2 and B3) - 1 mL
10006433Mycotoxines Fumonisines Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines. BiopureTM MIX 21 contains 10 µg/mL Fumonisin B1, 10 µg/mL Fumonisin B2 and 10 µg/mL Fumonisin B3 in acetonitrile/water.- Analyte: Fumonisin B1, Fumonisin B2, Fumonisin B3
- Technologie/Application: Calibrants
- Quantité/Montant: 1 mL

BiopureTM MIX 21 (Fumonisins B1, B2 and B3) - 5 mL
10006434Mycotoxines Fumonisines Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines. BiopureTM MIX 21 contains 10 µg/mL Fumonisin B1, 10 µg/mL Fumonisin B2 and 10 µg/mL Fumonisin B3 in acetonitrile/water.- Analyte: Fumonisin B1, Fumonisin B2, Fumonisin B3
- Technologie/Application: Calibrants
- Quantité/Montant: 5 mL

AgraStrip® Pro Ochratoxin A WATEX® - 50 G version
10007198Mycotoxines Ochratoxines LFD Quantitatif
The AgraStrip® Pro WATEX® test system enables the rapid and simple on-site quantification of mycotoxins in a variety of agricultural commodities. Both extraction and assay have been streamlined, reducing steps to a bare minimum while setting new standards in accuracy and usability. The test kits are available in a quantitative format and are used with the AgraVisionTM Pro reader, to provide objective results and secure a consistent results documentation.- Analyte: Ochratoxin A
- Technologie/Application: LFD
- Limite de détection: 0.5 ppb

Aflatoxins in corn, low level
10007113Mycotoxines Aflatoxines QCM
This Romer Labs QCM (quality control material) is a naturally contaminated corn sample which contains aflatoxins at defined levels. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Aflatoxin B1, aflatoxin B2, aflaotxin G1, aflatoxin G2
- Technologie/Application: QCM
- Plage de quantification/seuil: Afla B1: 5.1 ± 1.4 µg/kg
Afla B2: < 1 µg/kg
Afla G1: < 1 µg/kg
Afla G2: < 1 µg/kg

Afla, DON, ZON and FUM in corn, mid level
10007114Mycotoxines Aflatoxines Déoxynivalénol Fumonisines Trichotécènes B Zéaralénone QCM
This Romer Labs QCM (quality control material) is a naturally contaminated corn sample which contains aflatoxins, deoxynivalenol, zearalenone and fumonisins at defined levels. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Aflatoxins, deoxynivalenol, zearalenone, fumonisins
- Technologie/Application: QCM
- Plage de quantification/seuil: Aflatoxins: 6.8 ± 2.2 µg/kg
Deoxynivalenol: 1400 ± 600 µg/kg
Zearalenone: 109.6 ± 37.2 µg/kg
Fumonisins: 2200 ± 400 µg/kg

DON, T-2/HT-2 and OTA in wheat, low level
10007116Mycotoxines Déoxynivalénol Ochratoxines T-2/HT-2 Trichotécènes A Trichotécènes B QCM
This Romer Labs QCM (quality control material) is a naturally contaminated wheat sample which contains deoxynivalenol, T-2 toxin, HT-2 toxin and ochratoxin A at defined levels. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Deoxynivalenol, T-2 toxin, HT-2 toxin, ochratoxin A
- Technologie/Application: QCM
- Plage de quantification/seuil: Deoxynivalenol: 1000 ± 200 µg/kg
T-2 toxin: 49.1 ± 21.4 µg/kg
HT-2 toxin: 9.7 ± 4.2 µg/kg
Ochratoxin A: 8.3 ± 3.9 µg/kg

Deoxynivalenol in corn, high level
10007115Mycotoxines Déoxynivalénol Trichotécènes B QCM
This Romer Labs QCM (quality control material) is a naturally contaminated corn sample which contains deoxynivalenol at a defined level. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Deoxynivalenol
- Technologie/Application: QCM
- Plage de quantification/seuil: 2000 ± 600 µg/kg

Byonoy ELISA Reader
10007118ELISA Quantitatif
The byonoy ELISA reader is a microplate reader for 96-well assays. Its unique design, featuring 96 individual detection units, ensures the device is highly compact, robust, and reliable. The small footprint means it can be easily transported within or between different laboratories, giving you complete flexibility. In the often-crowded setting of the modern laboratory, this microplate reader aids in decentralizing important workflows. It increases access to instrumentation and brings readout directly to your workspace. Wavelengths: 405 nm, 450 nm, 492 nm, 630 nm (compatible with all Romer Labs ELISA test kits).- Technologie/Application: ELISA
- Type de résultat: Quantitatif
- Ports: USB 2.0 interface with PC