Mycotoxins
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>7</sub>]-Patulin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-single5mlvial_2.jpg)
BiopureTM U-[13C7]-Patulin - 25 µg/mL in acetonitrile
SH-13C7 Patulin in ACNMycotoxins Patulin C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Patulin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>24</sub>]-T-2 Toxin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_30.jpg)
BiopureTM U-[13C24]-T-2 Toxin - 25 µg/mL in acetonitrile
SH-13C24 T-2 in ACNMycotoxins T-2/HT-2* Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C T-2 Toxin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>22</sub>]-HT-2 Toxin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_31.jpg)
BiopureTM U-[13C22]-HT-2 Toxin - 25 µg/mL in acetonitrile
SH-13C22 HT-2 in ACNMycotoxins T-2/HT-2* Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C HT-2 Toxin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>18</sub>]-Zearalenone - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_23.jpg)
BiopureTM U-[13C18]-Zearalenone - 25 µg/mL in acetonitrile
SH-13C ZON in ACNMycotoxins Zearalenone C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Zearalenone
- Technology/Application: C13
- Solvent: Acetonitrile

BiopureTM Fusarium Toxins (NIV, DON, 3AcDON, T-2 Toxin, HT-2 Toxin, ZON) in acetonitrile
SH-Fusarium toxins ACNMycotoxins Deoxynivalenol* T-2/HT-2* Trichotecenes A Trichotecenes B Zearalenone Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Deoxynivalenol, HT-2 Toxin, T-2 Toxin, Zearalenone, 3-Acetyl-Deoxynivalenol, Nivalenol
- Technology/Application: Calibrants
- Solvent: Acetonitrile

BiopureTM Fumonisins in acetonitrile/water
SH-FUM in ACN-H2OMycotoxins Fumonisines Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Fumonisin B1, Fumonisin B2, Fumonisin B3
- Technology/Application: Calibrants
- Solvent: Acetonitrile/water 50/50

BiopureTM Aflatoxins in acetonitrile
SH-Afla in ACNMycotoxins Aflatoxins Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2, Aflatoxin M1
- Technology/Application: Calibrants
- Solvent: Acetonitrile

BiopureTM13C labelled Fussarium toxins (NIV, DON, 3AcDON, T-2 Toxin, HT-2 Toxin, ZON) in acetonitrile
SH-13C Fusarium Toxins in ACNMycotoxins Deoxynivalenol* T-2/HT-2* Trichotecenes A Trichotecenes B Zearalenone C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Deoxynivalenol, 13C HT-2 Toxin, 13C T-2 Toxin, 13C Zearalenon, 13C 3-Acetyl-Deoxynivalenol, 13C Nivalenol
- Technology/Application: C13
- Solvent: Acetonitrile

BiopureTM13C labelled Fumonisins in acetonitrile/water
SH-13C FUM in ACN/H2OMycotoxins Fumonisines C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Fumonisin B1, 13C Fumonisin B2, 13C Fumonisin B3
- Technology/Application: C13
- Verpackungseinheit: 1.2 mL
