Shop

RapidChek®E. coli O157 Test System
SH-E. coli Test SystemMicrobiology Pathogenic Bacteria LFD Qualitative
RapidChek®E. coli O157 test system offers an easy to prepare one-step enrichment media, without the need of additional supplements, combined with proprietary antibodies to detect the pathogenic E. coli serotype O157 (incl. H7) in various foodstuff within a minimum of 8 hours. Time to result: 8 - 18 hours (depending on the analyzed sample)- Analyte: E. coli O157 (including H7)
- Technology/Application: LFD
- Result type: Qualitative

RapidChek®Campylobacter Strips
SH-Campylobacter-StripsMicrobiology Pathogenic Bacteria LFD Qualitative
The RapidChek®Campylobacter test strips can be used with RapidChek®Campylobacter media (for 47 - 49 h time to result).- Analyte: C. jejuni, C. coli, C. lari
- Technology/Application: LFD
- Result type: Qualitative

RapidChek®Campylobacter Media
SH-Campylobacter-MediaMicrobiology Pathogenic Bacteria LFD Qualitative
The RapidChek®Campylobacter proprietary enrichment media needs no additional supplements. Media is added directly to sterile water and ready for use. Samples are incubated aerobically for a simplified enrichment procedure.- Analyte: C. jejuni, C. coli, C. lari
- Technology/Application: LFD
- Result type: Qualitative
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>7</sub>]-Patulin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-single5mlvial_2.jpg)
BiopureTM U-[13C7]-Patulin - 25 µg/mL in acetonitrile
SH-13C7 Patulin in ACNMycotoxins Patulin C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Patulin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>24</sub>]-T-2 Toxin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_30.jpg)
BiopureTM U-[13C24]-T-2 Toxin - 25 µg/mL in acetonitrile
SH-13C24 T-2 in ACNMycotoxins T-2/HT-2 Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C T-2 Toxin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>22</sub>]-HT-2 Toxin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_31.jpg)
BiopureTM U-[13C22]-HT-2 Toxin - 25 µg/mL in acetonitrile
SH-13C22 HT-2 in ACNMycotoxins T-2/HT-2 Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C HT-2 Toxin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>21</sub>]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_21.jpg)
BiopureTM U-[13C21]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile
SH-DON-3-Glucoside in ACNMycotoxins Deoxynivalenol Trichotecenes B Calibrants
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Deoxynivalenol-3-Glucoside
- Technology/Application: Calibrants
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>20</sub>]-Ochratoxin A - 10 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_22.jpg)
BiopureTM U-[13C20]-Ochratoxin A - 10 µg/mL in acetonitrile
SH-13C20 OTA in ACNMycotoxins Ochratoxins C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Ochratoxin A
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>18</sub>]-Zearalenone - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_23.jpg)
BiopureTM U-[13C18]-Zearalenone - 25 µg/mL in acetonitrile
SH-13C ZON in ACNMycotoxins Zearalenone C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Zearalenone
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>15</sub>]-Deoxynivalenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_24.jpg)
BiopureTM U-[13C15]-Deoxynivalenol - 25 µg/mL in acetonitrile
SH-13C15 DON in ACNMycotoxins Deoxynivalenol Trichotecenes B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Deoxynivalenol
- Technology/Application: C13
- Solvent: Acetonitrile