Shop

Aflatoxins in corn, low level
10007113Mycotoxins Aflatoxins QCM
This Romer Labs QCM (quality control material) is a naturally contaminated corn sample which contains aflatoxins at defined levels. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Aflatoxin B1, aflatoxin B2, aflaotxin G1, aflatoxin G2
- Technology/Application: QCM
- Quantitation range: Afla B1: 5.1 ± 1.4 µg/kg
Afla B2: < 1 µg/kg
Afla G1: < 1 µg/kg
Afla G2: < 1 µg/kg

Afla, DON, ZON and FUM in corn, mid level
10007114Mycotoxins Aflatoxins Deoxynivalenol Fumonisines Trichotecenes B Zearalenone QCM
This Romer Labs QCM (quality control material) is a naturally contaminated corn sample which contains aflatoxins, deoxynivalenol, zearalenone and fumonisins at defined levels. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Aflatoxins, deoxynivalenol, zearalenone, fumonisins
- Technology/Application: QCM
- Quantitation range: Aflatoxins: 6.8 ± 2.2 µg/kg
Deoxynivalenol: 1400 ± 600 µg/kg
Zearalenone: 109.6 ± 37.2 µg/kg
Fumonisins: 2200 ± 400 µg/kg

DON, T-2/HT-2 and OTA in wheat, low level
10007116Mycotoxins Deoxynivalenol Ochratoxins T-2/HT-2 Trichotecenes A Trichotecenes B QCM
This Romer Labs QCM (quality control material) is a naturally contaminated wheat sample which contains deoxynivalenol, T-2 toxin, HT-2 toxin and ochratoxin A at defined levels. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Deoxynivalenol, T-2 toxin, HT-2 toxin, ochratoxin A
- Technology/Application: QCM
- Quantitation range: Deoxynivalenol: 1000 ± 200 µg/kg
T-2 toxin: 49.1 ± 21.4 µg/kg
HT-2 toxin: 9.7 ± 4.2 µg/kg
Ochratoxin A: 8.3 ± 3.9 µg/kg

Deoxynivalenol in corn, high level
10007115Mycotoxins Deoxynivalenol Trichotecenes B QCM
This Romer Labs QCM (quality control material) is a naturally contaminated corn sample which contains deoxynivalenol at a defined level. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Deoxynivalenol
- Technology/Application: QCM
- Quantitation range: 2000 ± 600 µg/kg

AgraQuant® T-2/HT-2 ELISA Test
SH-AQ-T-2/HT-2Mycotoxins T-2/HT-2 ELISA Quantitative
The AgraQuant® T-2/HT-2 test kit is an accurate and reliable enzyme-linked immunosorbent assay (ELISA) in a quantitative format. Used in conjunction with an ELISA reader, such as the Byonoy Absorbance 96 or the BioTek model, it enables direct interpretation and continuous documentation of results. AgraQuant® T-2/HT-2 ELISA test kits are ideal for parallel measurement of multiple samples, offering incubation times as low as 20 minutes for up to 42 samples.- Analyte: T-2/HT-2
- Technology/Application: ELISA
- Limit of detection: 24 ppb

AgraStrip® Cry1Ac-S Bulk Grain - TraitChek
10001346GMO Protein Bt-Cry1Ac LFD Qualitative Quantitative
The AgraStrip® Cry1Ac-S Bulk Grain Strip Test is a ready-to-use lateral flow device (LFD) for on-site testing that detects the Cry1Ac protein in soybean.- Analyte: Cry1Ac
- Technology/Application: LFD
- Limit of detection: depends on method

AgraStrip® Pro RUR Bulk Grain Strip Test
10006554GMO Protein CP4 EPSPS LFD Quantitative
The AgraStrip® Pro RUR Bulk Grain test system enables the rapid and simple on-site quantification of RUR in soy. The AgraVisionTM Pro reader streamlines the entire assay, reducing steps to a bare minimum while setting new standards in accuracy and usability.- Analyte: CP4 EPSPS
- Technology/Application: LFD
- Quantitation range: 0.05 - 2 % (low LOD method)
0.1 - 5 % (regular range)

AgraStrip® Pro Allergen - Whole Egg
10007072Allergens Egg LFD Qualitative
The AgraStrip® Pro Whole Egg test kit is a lateral flow device (LFD) designed for the on-site detection of egg residues in raw materials, finished food products and beverages, rinse waters and environmental samples. They allow for the simple, fast and reliable qualitative detection of egg traces.- Analyte: Whole Egg
- Technology/Application: LFD
- Limit of detection: 2 ppm dried whole egg