Shop

Deoxynivalenol in corn, high level
10007115Mycotoxins Deoxynivalenol Trichotecenes B QCM
This Romer Labs QCM (quality control material) is a naturally contaminated corn sample which contains deoxynivalenol at a defined level. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Deoxynivalenol
- Technology/Application: QCM
- Quantitation range: 2000 ± 600 µg/kg

AgraQuant® T-2/HT-2 ELISA Test
SH-AQ-T-2/HT-2Mycotoxins T-2/HT-2 ELISA Quantitative
The AgraQuant® T-2/HT-2 test kit is an accurate and reliable enzyme-linked immunosorbent assay (ELISA) in a quantitative format. Used in conjunction with an ELISA reader, such as the Byonoy Absorbance 96 or the BioTek model, it enables direct interpretation and continuous documentation of results. AgraQuant® T-2/HT-2 ELISA test kits are ideal for parallel measurement of multiple samples, offering incubation times as low as 20 minutes for up to 42 samples.- Analyte: T-2/HT-2
- Technology/Application: ELISA
- Limit of detection: 24 ppb

AgraStrip® Cry1Ac-S Bulk Grain - TraitChek
10001346GMO Protein Bt-Cry1Ac LFD Qualitative Quantitative
The AgraStrip® Cry1Ac-S Bulk Grain Strip Test is a ready-to-use lateral flow device (LFD) for on-site testing that detects the Cry1Ac protein in soybean.- Analyte: Cry1Ac
- Technology/Application: LFD
- Limit of detection: depends on method

AgraStrip® Pro RUR Bulk Grain Strip Test
10006554GMO Protein CP4 EPSPS LFD Quantitative
The AgraStrip® Pro RUR Bulk Grain test system enables the rapid and simple on-site quantification of RUR in soy. The AgraVisionTM Pro reader streamlines the entire assay, reducing steps to a bare minimum while setting new standards in accuracy and usability.- Analyte: CP4 EPSPS
- Technology/Application: LFD
- Quantitation range: 0.05 - 2 % (low LOD method)
0.1 - 5 % (regular range)
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>10</sub>]-Tenuazonic acid - 10 µg/mL Dried Down BO MT TEST AWS 1](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_55.jpg)
BiopureTM U-[13C10]-Tenuazonic acid - 10 µg/mL Dried Down BO MT TEST AWS 1
10007037Mycotoxins Alternaria Toxins C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Tenuazonic acid
- Technology/Application: C13
- Molecular weight (g/mol): 197.23

CytoQuant® Electrolyte Solution
10007030Microbiology Food Residue Indicator Microorganisms Mobile Flow Cytometer Quantitative Semi-Quantitative
The CytoQuant® Electrolyte Solution was specifically developed for the CytoQuant® mobile flow cytometer and it is intended for the adjustment of the conductivity of liquid samples to be measured with the device. The solution is practically free of bacteria and other particles.- Technology/Application: Mobile Flow Cytometer
- Result type: Quantitative, Semi-Quantitative
- Product/Environment: Environmental Monitoring, Product Testing

CytoQuant® Cleaning Vial
10007028Microbiology Food Residue Indicator Microorganisms Mobile Flow Cytometer
The CytoQuant® Cleaning Vial was developed specifically for the CytoQuant® mobile flow cytometer and is used to remove larger pieces of debris, foodstuffs, and other particles that may be introduced into the flow system.- Technology/Application: Mobile Flow Cytometer
- Quantity/Amount: 72
- Storage Temperature: 15°C - 25°C
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>17</sub>]-Aflatoxin M1 - 0.5 µg/mL in acetonitrile, 5 mL](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle5mlvial_18.jpg)
BiopureTM U-[13C17]-Aflatoxin M1 - 0.5 µg/mL in acetonitrile, 5 mL
10007022Mycotoxins Aflatoxins C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Aflatoxin M1
- Technology/Application: C13
- Quantity/Amount: 5 mL