Shop

AgraQuant® Toasted Meal - GMOChek
10001453GMO Protein CP4 EPSPS ELISA Quantitative
The AgraQuant® Toasted Meal test is an enzyme-linked immunosorbent assay (ELISA) that detects quantitatively the CP4 EPSPS protein in Roundup Ready® soybeans.- Analyte: CP4 EPSPS
- Technology/Application: ELISA
- Result type: Quantitative

AgraQuant® PMI - SeedChek
10001449GMO Protein PMI ELISA Quantitative
The AgraQuant® PMI test is an enzyme-linked immunosorbent assay (ELISA) that detects qualitatively the PMI protein in corn kernel and leaf, rice seed and leaf, and bulk non-GM or conventional corn and rice.- Analyte: PMI
- Technology/Application: ELISA
- Result type: Quantitative
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>7</sub>]-Patulin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-single5mlvial_2.jpg)
BiopureTM U-[13C7]-Patulin - 25 µg/mL in acetonitrile
SH-13C7 Patulin in ACNMycotoxins Patulin C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Patulin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>24</sub>]-T-2 Toxin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_30.jpg)
BiopureTM U-[13C24]-T-2 Toxin - 25 µg/mL in acetonitrile
SH-13C24 T-2 in ACNMycotoxins T-2/HT-2 Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C T-2 Toxin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>22</sub>]-HT-2 Toxin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_31.jpg)
BiopureTM U-[13C22]-HT-2 Toxin - 25 µg/mL in acetonitrile
SH-13C22 HT-2 in ACNMycotoxins T-2/HT-2 Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C HT-2 Toxin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>21</sub>]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_21.jpg)
BiopureTM U-[13C21]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile
SH-DON-3-Glucoside in ACNMycotoxins Deoxynivalenol Trichotecenes B Calibrants
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Deoxynivalenol-3-Glucoside
- Technology/Application: Calibrants
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>20</sub>]-Ochratoxin A - 10 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_22.jpg)
BiopureTM U-[13C20]-Ochratoxin A - 10 µg/mL in acetonitrile
SH-13C20 OTA in ACNMycotoxins Ochratoxins C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Ochratoxin A
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>18</sub>]-Zearalenone - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_23.jpg)
BiopureTM U-[13C18]-Zearalenone - 25 µg/mL in acetonitrile
SH-13C ZON in ACNMycotoxins Zearalenone C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Zearalenone
- Technology/Application: C13
- Solvent: Acetonitrile

