Mycotoxins

MycoSep 228 AflaPat
10001955Mycotoxins Aflatoxins Patulin SPE Columns
MycoSep® columns contain a mixture of adsorbent materials designed for clean-up of all relevant food and feed commodities. These cost efficient clean-up columns are part of official AOAC and CEN methods and allow high sample throughput.- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2, Patulin
- Technology/Application: SPE Columns
- Number of columns: 25

MultiSep 228 AflaPat
10001943Mycotoxins Aflatoxins Patulin SPE Columns
MultiSep® columns contain a mixture of adsorbent materials designed for clean-up of all relevant food and feed commodities. These cost efficient clean-up columns are part of official AOAC and CEN methods and allow high sample throughput.- Analyte: Aflatoxins, Patulin
- Technology/Application: SPE Columns
- Number of columns: 25

MultiSep 216 Trich
10001938Mycotoxins Trichotecenes A Trichotecenes B SPE Columns
MultiSep® columns contain a mixture of adsorbent materials designed for clean-up of all relevant food and feed commodities. These cost efficient clean-up columns are part of official AOAC and CEN methods and allow high sample throughput.- Analyte: Thrichotecenes A, Trichotecenes B
- Technology/Application: SPE Columns
- Number of columns: 25

BiopureTM Patulin Solid Standards
10000315Mycotoxins Patulin Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Patulin
- Technology/Application: Calibrants
- Quantity/Amount: 5 mg

MycoSep® Trich
SH-MycoSep TrichMycotoxins Trichotecenes A Trichotecenes B SPE Columns
MycoSep® columns contain a mixture of adsorbent materials designed for clean-up of all relevant food and feed commodities. These cost efficient clean-up columns are part of official AOAC and CEN methods and allow high sample throughput.- Analyte: Thrichotecenes A, Trichothecenes B
- Technology/Application: SPE Columns
- Format: Push-through

MultiSep Trich
SH-MultiSep TrichMycotoxins Trichotecenes A Trichotecenes B SPE Columns
MultiSep® columns contain a mixture of adsorbent materials designed for clean-up of all relevant food and feed commodities. These cost efficient clean-up columns are part of official AOAC and CEN methods and allow high sample throughput.- Analyte: Thrichotecenes A, Trichotecenes B
- Technology/Application: SPE Columns
- Format: Column

DonStar Immunoaffinity columns
SH-DonStar IACMycotoxins Deoxynivalenol Trichotecenes B Immunoaffinity Columns
StarLineTM immunoaffinity columns are designed for simple and reliable clean-up of a broad range of commodities, including feed. StarLineTM immunoaffinity columns can be used for purification and concentration of mycotoxins prior to analyses with HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.- Analyte: Deoxynivalenol
- Technology/Application: Immunoaffinity Columns
- Product/Environment: Product Testing
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>7</sub>]-Patulin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-single5mlvial_2.jpg)
BiopureTM U-[13C7]-Patulin - 25 µg/mL in acetonitrile
SH-13C7 Patulin in ACNMycotoxins Patulin C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Patulin
- Technology/Application: C13
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>21</sub>]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_21.jpg)
BiopureTM U-[13C21]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile
SH-DON-3-Glucoside in ACNMycotoxins Deoxynivalenol Trichotecenes B Calibrants
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Deoxynivalenol-3-Glucoside
- Technology/Application: Calibrants
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>15</sub>]-Deoxynivalenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_24.jpg)
BiopureTM U-[13C15]-Deoxynivalenol - 25 µg/mL in acetonitrile
SH-13C15 DON in ACNMycotoxins Deoxynivalenol Trichotecenes B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Deoxynivalenol
- Technology/Application: C13
- Solvent: Acetonitrile