Mycotoxins
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>21</sub>]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_21.jpg)
BiopureTM U-[13C21]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile
SH-DON-3-Glucoside in ACNMycotoxins Deoxynivalenol Trichotecenes B Calibrants
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Deoxynivalenol-3-Glucoside
- Technology/Application: Calibrants
- Solvent: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>15</sub>]-Deoxynivalenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_24.jpg)
BiopureTM U-[13C15]-Deoxynivalenol - 25 µg/mL in acetonitrile
SH-13C15 DON in ACNMycotoxins Deoxynivalenol Trichotecenes B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Deoxynivalenol
- Technology/Application: C13
- Solvent: Acetonitrile

BiopureTM Nivalenol Hydrate Solid Standards
SH-Nivalenol Hydrate Solid StandardMycotoxins Trichotecenes B Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Nivalenol hydrate
- Technology/Application: Calibrants
- Formula: C15H20O7

BiopureTM Nivalenol - 100 µg/mL in acetonitrile
SH-NIV in ACNMycotoxins Trichotecenes B Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Nivalenol
- Technology/Application: Calibrants
- Solvent: Acetonitrile

BiopureTM Neosolaniol Solid Standards
SH-Neosolaniol Solid StandardsMycotoxins Trichotecenes B Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Neosolaniol
- Technology/Application: Calibrants
- Formula: C19H26O8

BiopureTM MIX 4 (A- and B-Trichothecenes, Zearalenone)
SH-MIX 4 in ACNMycotoxins Trichotecenes A Trichotecenes B Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines. BiopureTM MIX 1 contains 10 µg/mL each 3-acetyl-deoxynivalenol, deoxynivalenol, nivalenol, fusarenon-X, HT-2 toxin, T-2 toxin, diacetoxyscirpenol and zearalenone in acetonitrile- Analyte: 3-Acetyl-Deoxynivalenol, Deoxynivalenol, Fusarenon X, HT-2 Toxin, T-2 Toxin, Diacetoxyscirpenol, Zearalenone
- Technology/Application: Calibrants
- Solvent: Acetonitrile

BiopureTM MIX 3 (Fumonisins)
SH-MIX 3 in ACNMycotoxins Fumonisines Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines. BiopureTM MIX 3 contains 50 µg/mL each Fumonisin B1, Fumonisin B2 in acetonitrile/water 50/50.- Analyte: Fumonisin B1, Fumonisin B2
- Technology/Application: Calibrants
- Solvent: Acetonitrile/water 50/50

BiopureTM MIX 2 (B-Trichothecenes)
SH-MIX 2 in ACNMycotoxins Deoxynivalenol Trichotecenes B Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines. BiopureTM MIX 2 contains 100 µg/mL each of deoxynivalenol, nivalenol, 3-acetyl-deoxynivalenol, 15-acetyl-deoxynivalenol in acetonitrile- Analyte: Deoxynivalenol, Nivalenol, 3-Acetyl-Deoxynivalenol, 15-Acetyl-Deoxynivalenol
- Technology/Application: Calibrants
- Solvent: Acetonitrile

BiopureTM ISO 17034 (Certified) Reference Materials
SH-ISO 17034 (C)RMMycotoxins Aflatoxins Deoxynivalenol Fumonisines Ochratoxins T-2/HT-2 Trichotecenes A Trichotecenes B Zearalenone ISO17034
BiopureTM ISO 17034 (Certified) Reference Materials are produced under the ISO 17034 accreditation and fulfill all requirements specified in the ISO 17034 (General requirements for the competence of reference material producers) including metrological traceability, stability and homogeneity. ISO 17034 Certified Reference Materials (CRMs) are fully metrologically traceable in that their measurements of concentration and uncertainty relate to certified materials available on the market through an unbroken chain of comparisons with stated uncertainties; CRMs are furthermore well characterized by several competent analytical labs. This ensures that the certified value with uncertainty can be calculated with a high degree of reliability. In the case of some mycotoxins, certified materials typically used to ensure such a high level of traceability are not available. Although these materials undergo the same process of characterization according to ISO 17034, they cannot be considered certified; these are simply called ISO 17034 Reference Materials (RMs).- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2, T-2 Toxin, HT-2 Toxin, Nivalenol, Deoxynivalenol, Zearalenone, Ochratoxin A, Fumonisin B1, Fumonisin B2, Patulin
- Technology/Application: ISO17034
- Product/Environment: Product Testing

BiopureTM Fusarium Toxins (NIV, DON, 3AcDON, T-2 Toxin, HT-2 Toxin, ZON) in acetonitrile
SH-Fusarium toxins ACNMycotoxins Deoxynivalenol T-2/HT-2 Trichotecenes A Trichotecenes B Zearalenone Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Deoxynivalenol, HT-2 Toxin, T-2 Toxin, Zearalenone, 3-Acetyl-Deoxynivalenol, Nivalenol
- Technology/Application: Calibrants
- Solvent: Acetonitrile