BiopureTM ISO 17034 (Certified) Reference Materials
SH-ISO 17034 (C)RMMycotoxins Aflatoxins Deoxynivalenol Fumonisines Ochratoxins T-2/HT-2 Trichotecenes A Trichotecenes B Zearalenone ISO17034
BiopureTM ISO 17034 (Certified) Reference Materials are produced under the ISO 17034 accreditation and fulfill all requirements specified in the ISO 17034 (General requirements for the competence of reference material producers) including metrological traceability, stability and homogeneity. ISO 17034 Certified Reference Materials (CRMs) are fully metrologically traceable in that their measurements of concentration and uncertainty relate to certified materials available on the market through an unbroken chain of comparisons with stated uncertainties; CRMs are furthermore well characterized by several competent analytical labs. This ensures that the certified value with uncertainty can be calculated with a high degree of reliability. In the case of some mycotoxins, certified materials typically used to ensure such a high level of traceability are not available. Although these materials undergo the same process of characterization according to ISO 17034, they cannot be considered certified; these are simply called ISO 17034 Reference Materials (RMs).- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2, T-2 Toxin, HT-2 Toxin, Nivalenol, Deoxynivalenol, Zearalenone, Ochratoxin A, Fumonisin B1, Fumonisin B2, Patulin
- Technology/Application: ISO17034
- Product/Environment: Product Testing

BiopureTM Aflatoxins Solid Standards
SH-Afla Solid StandardsMycotoxins Aflatoxins Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2
- Technology/Application: Calibrants
- Quantity/Amount: 5 mg

BiopureTM Aflatoxins in acetonitrile
SH-Afla in ACNMycotoxins Aflatoxins Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2, Aflatoxin M1
- Technology/Application: Calibrants
- Solvent: Acetonitrile

BiopureTM 13C labelled Aflatoxins in acetonitrile
SH-13C Afla in ACNMycotoxins Aflatoxins C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Aflatoxin B1, 13C Aflatoxin B2, 13C Aflatoxin G1, 13C Aflatoxin G2, 13C Aflatoxin M1
- Technology/Application: C13
- Quantity/Amount: 1.2 mL

BiopureTM EN 17641:2022 Reference Materials
SH-EN 17641 MixesMycotoxins Aflatoxins Deoxynivalenol Fumonisines T-2/HT-2 Trichotecenes A Trichotecenes B Zearalenone Calibrants
Biopure™ EN 17641 Reference Materials are mixes of “normal” (12C) or internal stable isotope-labeled (13C) reference materials specially designed for analytical laboratories that employ the EN 17641:2022 multi-mycotoxin method with LC-MS/MS. EN 17641:2022 was established by CEN (The European Committee for Standardization) in September 2022. It defines a multi-method that determines the following common mycotoxins by LC-MS/MS in foodstuffs:aflatoxins, deoxynivalenol, fumonisins, ochratoxin A, T-2 toxin, HT-2 toxin and zearalenone. It includes information about reagents, apparatus and equipment, method parameters as well as reference materials.- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2, Aflatoxin M1, Fumonisin B1, Fumonisin B2, Deoxynivalenol, 3-Acetyl-Deoxynivalenol, Nivalenol, HT-2 Toxin, T-2 Toxin, Zearalenone
- Technology/Application: Calibrants
- Quantity/Amount: 5 mL

AgraStrip® Aflatoxin WATEX® Quantitative Tests
SH-AS-Afla-WATEXLFD Quantitative
The AgraStrip® WATEX® test kits are ready-to-use lateral flow devices (LFD) for on-site testing. These allow a rapid analysis of a wide range of food and feed samples with an assay time of 3 minutes. The eco-friendly One for All WATEX extraction makes the analysis of multiple mycotoxins possible from only a single water-based sample extract. The test kits are available in a quantitative format and are used with the AgraVision™ reader, to provide objective results and secure a consistent results documentation.- Analyte: total aflatoxin
- Technology/Application: LFD
- Limit of detection: 3.3 ppb

AgraQuant® Total Aflatoxin ELISA Test
SH-AQ-Aflatoxin-TotalELISA Quantitative
AgraQuant® Total Aflatoxin test kits are accurate and reliable enzyme-linked immunosorbent assays (ELISA) in a quantitative format. Together with a StatFax® or BioTek® ELISA reader, results can be directly interpreted and continuously documented. These ELISA test kits are the ideal solution for a parallel measurement of multiple samples with incubation times of as low as 15 minutes for up to 42 samples. With the AgraQuant® ELISA, up to 6 mycotoxins can be analyzed from 1 extraction, substantially shortening overall time-to-result.- Analyte: Aflatoxin B1, B2, G1, G2
- Technology/Application: ELISA
- Result type: Quantitative

AgraQuant® Aflatoxin M1 ELISA test
SH-AQ-Aflatoxin-M1ELISA Quantitative
AgraQuant® M1 test kits are accurate and reliable enzyme-linked immunosorbent assays (ELISA) in a quantitative format. Together with a StatFax® or BioTek® ELISA reader, results can be directly interpreted and continuously documented. These ELISA test kits are the ideal solution for an accurate measurement of multiple samples in a very broad quantitation range.- Analyte: Aflatoxin M1
- Technology/Application: ELISA
- Result type: Quantitative

AgraQuant® Aflatoxin B1 ELISA test
SH-AQ-Aflatoxin-B1ELISA Quantitative
AgraQuant® test kits are accurate and reliable enzyme-linked immunosorbent assays (ELISA) in a quantitative format. Together with a StatFax® or BioTek® ELISA reader, results can be directly interpreted and continuously documented. These ELISA test kits are the ideal solution for a parallel measurement of multiple samples with incubation times of as low as 15 minutes for up to 42 samples.- Analyte: Aflatoxin B1
- Technology/Application: ELISA
- Limit of detection: 2 ppb

AflaStar Immunoaffinity Columns
SH-AflaStar IACMycotoxins Aflatoxins Immunoaffinity Columns
StarLineTM immunoaffinity columns are designed for simple and reliable clean-up of a broad range of commodities, including feed. StarLineTM immunoaffinity columns can be used for purification and concentration of mycotoxins prior to analyses with HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2
- Technology/Application: Immunoaffinity Columns
- Product/Environment: Product Testing