Mycotoxins

DON, T-2/HT-2 and OTA in wheat, low level
10007116Mycotoxins Deoxynivalenol Ochratoxins T-2/HT-2 Trichotecenes A Trichotecenes B QCM
This Romer Labs QCM (quality control material) is a naturally contaminated wheat sample which contains deoxynivalenol, T-2 toxin, HT-2 toxin and ochratoxin A at defined levels. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Analyte: Deoxynivalenol, T-2 toxin, HT-2 toxin, ochratoxin A
- Technology/Application: QCM
- Quantitation range: Deoxynivalenol: 1000 ± 200 µg/kg
T-2 toxin: 49.1 ± 21.4 µg/kg
HT-2 toxin: 9.7 ± 4.2 µg/kg
Ochratoxin A: 8.3 ± 3.9 µg/kg
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>24</sub>]-T-2 Toxin - 25 µg/mL in acetonitrile, 5 mL](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle5mlvial_17.jpg)
BiopureTM U-[13C24]-T-2 Toxin - 25 µg/mL in acetonitrile, 5 mL
10006994Mycotoxins T-2/HT-2 Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C T-2 Toxin
- Technology/Application: C13
- Quantity/Amount: 5 mL

MultiStar Immunoaffinity Columns
10005407Mycotoxins Aflatoxins Fumonisines Ochratoxins Trichotecenes A Trichotecenes B Zearalenone Immunoaffinity Columns
StarLineTM immunoaffinity columns are designed for simple and reliable clean-up of a broad range of commodities. StarLineTM immunoaffinity columns can be used for purification and concentration of mycotoxins and vitamins prior to analyses with HPLC, GC-MS or LC-MS.- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2, Ochratoxin, Zearalenone, Deoxynivalenol, Fumonisin B1, Fumonisin B2, T-2 Toxin, HT-2 Toxin
- Technology/Application: Immunoaffinity Columns
- Number of columns: 25

BiopureTM T-2 Tetraol - 50 µg/mL
10003671Mycotoxins T-2/HT-2 Trichotecenes A Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: T-2 Tetraol
- Technology/Application: Calibrants
- Quantity/Amount: 1 mL

BiopureTM T-2 Triol - 50 µg/mL
10003670Mycotoxins T-2/HT-2 Trichotecenes A Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: T-2 Triol
- Technology/Application: Calibrants
- Quantity/Amount: 1 mL

Wheat, blank
10003611Mycotoxins Aflatoxins Deoxynivalenol Fumonisines Ochratoxins T-2/HT-2 Trichotecenes A Trichotecenes B Zearalenone QCM
This Romer Labs QCM (quality control material) is a blank wheat sample. QCMs can be used for validating methods, periodic accuracy checks of accredited analytical methods, and as positive control materials in different assays.- Technology/Application: QCM
- Quantitation range: < Limit of Detection
- Quantity/Amount: 100 g

BiopureTM 15-Acetoxyscirpenol In Acetonitrile - 50 µg/mL
10002875Mycotoxins Trichotecenes A Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: 15-Acetoxyscirpenol
- Technology/Application: Calibrants
- Quantity/Amount: 1 mL on request
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>19</sub>] - Diacetoxyscirpenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_52.jpg)
BiopureTM U-[13C19] - Diacetoxyscirpenol - 25 µg/mL in acetonitrile
10002831Mycotoxins Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Diacetoxyscirpenol
- Technology/Application: C13
- Quantity/Amount: 1.2 mL

T2/HT2 Star R Immunoaffinity columns
10001977Mycotoxins T-2/HT-2 Trichotecenes A Immunoaffinity Columns
StarLine™ immunoaffinity columns are designed for simple and reliable clean-up of a broad range of commodities, including feed. StarLine™ immunoaffinity columns can be used for purification and concentration of mycotoxins prior to analyses with HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.- Analyte: T-2 Toxin, HT-2 Toxin
- Technology/Application: Immunoaffinity Columns
- Number of columns: 25
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>22</sub>]-HT-2 Toxin - 25 µg/mL in acetonitrile, 5 mL](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle5mlvial_13.jpg)