Mycotoxins
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>15</sub>]-Nivalenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_53.jpg)
BiopureTM U-[13C15]-Nivalenol - 25 µg/mL in acetonitrile
10002829Mycotoxins Trichotecenes B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Nivalenol
- Technology/Application: C13
- Quantity/Amount: 1.2 mL
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>18</sub>]-Sterigmatocystine - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_54.jpg)
BiopureTM U-[13C18]-Sterigmatocystine - 25 µg/mL in acetonitrile
10002828Mycotoxins Sterigmatocystin C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Sterigmatocystin
- Technology/Application: C13
- Quantity/Amount: 1.2 mL
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>17</sub>]-Mycophenolic Acid - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_57.jpg)
BiopureTM U-[13C17]-Mycophenolic Acid - 25 µg/mL in acetonitrile
10002823Mycotoxins Mycophenolic Acid C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Mycophenolic acid
- Technology/Application: C13
- Quantity/Amount: 1.2 mL on request
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>17</sub>]-3-Acetyl-Deoxynivalenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_61.jpg)
BiopureTM U-[13C17]-3-Acetyl-Deoxynivalenol - 25 µg/mL in acetonitrile
10002811Mycotoxins Deoxynivalenol Trichotecenes B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C 3-Acetyl-Deoxynivalenol
- Technology/Application: C13
- Quantity/Amount: 1.2 mL

T2/HT2 Star R Immunoaffinity columns
10001977Mycotoxins T-2/HT-2 Trichotecenes A Immunoaffinity Columns
StarLine™ immunoaffinity columns are designed for simple and reliable clean-up of a broad range of commodities, including feed. StarLine™ immunoaffinity columns can be used for purification and concentration of mycotoxins prior to analyses with HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.- Analyte: T-2 Toxin, HT-2 Toxin
- Technology/Application: Immunoaffinity Columns
- Number of columns: 25

FumoniStar Immunoaffinity columns
10001971Mycotoxins Fumonisines Immunoaffinity Columns
StarLine™ immunoaffinity columns are designed for simple and reliable clean-up of a broad range of commodities, including feed. StarLine™ immunoaffinity columns can be used for purification and concentration of mycotoxins prior to analyses with HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.- Analyte: Fumonisin B1, Fumonisin B2, Fumonisin B3
- Technology/Application: Immunoaffinity Columns
- Number of columns: 25

AflaStar R M1
10001964Mycotoxins Aflatoxins Immunoaffinity Columns
StarLineTM immunoaffinity columns are designed for simple and reliable clean-up of a broad range of commodities, including feed. StarLineTM immunoaffinity columns can be used for purification and concentration of mycotoxins prior to analyses with HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.- Analyte: Aflatoxin M1
- Technology/Application: Immunoaffinity Columns
- Number of columns: 25

BiopureTM Atropine - 100 µg/mL dried down
10001831Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Atropine
- Technology/Application: Calibrants
- Quantity/Amount: 1 mL

BiopureTM Ergotaminine - 25 µg/mL dried down
10000367Mycotoxins Ergot Alkaloids Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Ergotaminine
- Technology/Application: Calibrants
- Quantity/Amount: 0.125 mg

BiopureTM Ergocryptinine - 25 µg/mL dried down
10000366Mycotoxins Ergot Alkaloids Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Ergocryptinine
- Technology/Application: Calibrants
- Quantity/Amount: 0.125 mg