Micotossine
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>19</sub>] - Diacetoxyscirpenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_52.jpg)
BiopureTM U-[13C19] - Diacetoxyscirpenol - 25 µg/mL in acetonitrile
10002831Micotossine Tricoteceni di tipo A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analita: 13C Diacetoxyscirpenol
- Tecnologia/Applicazione: C13
- Quantità/ammontare: 1.2 mL
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>15</sub>]-Nivalenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_53.jpg)
BiopureTM U-[13C15]-Nivalenol - 25 µg/mL in acetonitrile
10002829Micotossine Tricoteceni di tipo B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analita: 13C Nivalenol
- Tecnologia/Applicazione: C13
- Quantità/ammontare: 1.2 mL
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>18</sub>]-Sterigmatocystine - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_54.jpg)
BiopureTM U-[13C18]-Sterigmatocystine - 25 µg/mL in acetonitrile
10002828Micotossine Sterigmatocistina C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analita: 13C Sterigmatocystin
- Tecnologia/Applicazione: C13
- Quantità/ammontare: 1.2 mL
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>17</sub>]-Mycophenolic Acid - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_57.jpg)
BiopureTM U-[13C17]-Mycophenolic Acid - 25 µg/mL in acetonitrile
10002823Micotossine Acido micofenolicoAcid C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analita: 13C Mycophenolic acid
- Tecnologia/Applicazione: C13
- Quantità/ammontare: 1.2 mL on request
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>17</sub>]-3-Acetyl-Deoxynivalenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_61.jpg)
BiopureTM U-[13C17]-3-Acetyl-Deoxynivalenol - 25 µg/mL in acetonitrile
10002811Micotossine Deossinivalenolo Tricoteceni di tipo B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analita: 13C 3-Acetyl-Deoxynivalenol
- Tecnologia/Applicazione: C13
- Quantità/ammontare: 1.2 mL
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>7</sub>]-Patulin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-single5mlvial_2.jpg)
BiopureTM U-[13C7]-Patulin - 25 µg/mL in acetonitrile
SH-13C7 Patulin in ACNMicotossine Patulina C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analita: 13C Patulin
- Tecnologia/Applicazione: C13
- Solvente: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>24</sub>]-T-2 Toxin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_30.jpg)
BiopureTM U-[13C24]-T-2 Toxin - 25 µg/mL in acetonitrile
SH-13C24 T-2 in ACNMicotossine T-2/HT-2 Tricoteceni di tipo A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analita: 13C T-2 Toxin
- Tecnologia/Applicazione: C13
- Solvente: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>22</sub>]-HT-2 Toxin - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_31.jpg)
BiopureTM U-[13C22]-HT-2 Toxin - 25 µg/mL in acetonitrile
SH-13C22 HT-2 in ACNMicotossine T-2/HT-2 Tricoteceni di tipo A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analita: 13C HT-2 Toxin
- Tecnologia/Applicazione: C13
- Solvente: Acetonitrile
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>21</sub>]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopure-referencematerials-new_21.jpg)
BiopureTM U-[13C21]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile
SH-DON-3-Glucoside in ACNMicotossine Deossinivalenolo Tricoteceni di tipo B Standard Analitici
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analita: 13C Deoxynivalenol-3-Glucoside
- Tecnologia/Applicazione: Standard Analitici
- Solvente: Acetonitrile
