Mycotoxins

BiopureTM Deoxynivalenol-3-Glucoside - 50 µg/mL, 5 mL
10003522Mycotoxins Deoxynivalenol Trichotecenes B Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Deoxynivalenol-3-glucoside
- Technology/Application: Calibrants
- Quantity/Amount: 5 mL

BiopureTM Hydrolyzed Fumonisin B1 - 25 µg/mL In Acetonitrile/Water
10002873Mycotoxins Fumonisines Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO 33401:2024 and Eurachem guidelines.- Analyte: Hydrolyzed Fumonisin B1
- Technology/Application: Calibrants
- Quantity/Amount: 1 mL on request
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>17</sub>]-15-Acetyl-Deoxynivalenol - 10 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_60.jpg)
BiopureTM U-[13C17]-15-Acetyl-Deoxynivalenol - 10 µg/mL in acetonitrile
10002840Mycotoxins Deoxynivalenol Trichotecenes B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C 15-Acetyl-Deoxynivalenol
- Technology/Application: C13
- Quantity/Amount: 1.2 mL
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>15</sub>]-Nivalenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_53.jpg)
BiopureTM U-[13C15]-Nivalenol - 25 µg/mL in acetonitrile
10002829Mycotoxins Trichotecenes B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Nivalenol
- Technology/Application: C13
- Quantity/Amount: 1.2 mL
![Biopure<sup>TM</sup> U-[<sup>13</sup>C<sub>17</sub>]-3-Acetyl-Deoxynivalenol - 25 µg/mL in acetonitrile](https://stage-m-romerlabs-upgrade.ecxdev.io/media/catalog/product/cache/878561f3b19c3b17be00a0445aafeae8/B/i/Biopuresingle1mlvial_61.jpg)
BiopureTM U-[13C17]-3-Acetyl-Deoxynivalenol - 25 µg/mL in acetonitrile
10002811Mycotoxins Deoxynivalenol Trichotecenes B C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C 3-Acetyl-Deoxynivalenol
- Technology/Application: C13
- Quantity/Amount: 1.2 mL

FumoniStar Immunoaffinity columns
10001971Mycotoxins Fumonisines Immunoaffinity columns
StarLine™ immunoaffinity columns are designed for simple and reliable clean-up of a broad range of commodities, including feed. StarLine™ immunoaffinity columns can be used for purification and concentration of mycotoxins prior to analyses with HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.- Analyte: Fumonisin B1, Fumonisin B2, Fumonisin B3
- Technology/Application: Immunoaffinity columns
- Number of columns: 25

MycoSpin 400 Multimycotoxin
10001961Mycotoxins Aflatoxins Fumonisines Ochratoxins Trichotecenes A Trichotecenes B Zearalenone SPE columns
The MycoSpinTM 400 Multitoxin column contains a combination of adsorbents that was designed for the purification of complex commodity extracts for subsequent LC-MS/MS multi-mycotoxin analysis.- Analyte: Aflatoxins, Thichotecenes, Fumonisins, Ochratoxins, Zearalenone
- Technology/Application: SPE columns
- Number of columns: 25

MultiSep 211 Fumonisins
10001937Mycotoxins Fumonisines SPE columns
MultiSep® columns contain a mixture of adsorbent materials designed for clean-up of all relevant food and feed commodities. These cost efficient clean-up columns are part of official AOAC and CEN methods and allow high sample throughput.- Analyte: Fumonisines
- Technology/Application: SPE columns
- Number of columns: 25

MycoSep® Trich
SH-MycoSep TrichMycotoxins Trichotecenes A Trichotecenes B SPE columns
MycoSep® columns contain a mixture of adsorbent materials designed for clean-up of all relevant food and feed commodities. These cost efficient clean-up columns are part of official AOAC and CEN methods and allow high sample throughput.- Analyte: Thrichotecenes A, Trichothecenes B
- Technology/Application: SPE columns
- Format: Push-through

MultiSep Trich
SH-MultiSep TrichMycotoxins Trichotecenes A Trichotecenes B SPE columns
MultiSep® columns contain a mixture of adsorbent materials designed for clean-up of all relevant food and feed commodities. These cost efficient clean-up columns are part of official AOAC and CEN methods and allow high sample throughput.- Analyte: Thrichotecenes A, Trichotecenes B
- Technology/Application: SPE columns
- Format: Column